inverter,s stopping method selection and prohibition of reverse operation .
stopping method selection
used to set the stopping method . 0:ramp to stop . 1:coast to stop . 2:dc injection braking stop (stops faster than coast to stop . no regenerative operation) 3:coast to stop with timer run commands are disregarded during deceleration .
note :
please set the stopping method while the stopping command is input . only setting 0 and 1 can be used with flux vector control.
prohibition of reverse operation
to set reverse operation. 0:reverse enable .1:reverse disable .
note :
when this command was input ,the function to set the motor,s forward operation or reverse operation will be disable . it is used in the application where reverse operation is prohibited .