Friday 24 June 2016

THE OPERATOR'S LAYOUT OF INVERTER

THE OPERATOR'S LAYOUT OF INVERTER
1 constant display screen.
2 exterior input operating command indicator.
3 exterior input frequency command indicator.
4 stop indicator.
5 stop.
6 menu.
7 return.
8 increment.
 9 access.
10 shift/reset.
11 for/rev.
12 decrement.
13 jog.
14 operation mode selection key.
15 operation key.
16 operator operation indicator.
17 reverse operation indicator.
18 forward operation indicator.
19 driving mode indicator.
constant display screen.
it is 5-bit led display screen to display the function code and setting value and monitored value.
remote control indicator.
seq indicator will be lighted when circuit terminal inputs operating command ref indicator will be
when the frequency is input by control circuit terminal 13'14.
operation direction indicator.
fwd will be on in forward operation.rev will be on in reverse operation.
driving mode indicator.
the indicator is lighted only when selecting the driving mode.

  OPERATOR'S DISPLAY STATUS OF INVERTER.

when this inverter is powered on'the operator's led
screen will display the company's cod and then it
comes to the constant check method and display the current frequency setting (f) in this stats 'the current
frequency setting'output frequency setting output
current setting (a) output voltage setting (u) and other constant (u) which can be monitored will be
displayed on the screen in consequence.the key (menu) can also effect the switch over between check method (monitored constants) and program method (other operating constant).the shift of each monitored constants can be achieved by decrement'increment and shift key under the status of other di-
splayed constant (u--) access key can display and set the data. to press (esc) to return to the check m-
ethod displaying status. since the variable constants and function inverter are summarized in menu'it is e-
asy to set the constants.inverter has two power on status.